Avago-technologies eXtremeRAID 2000 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Sprzęt komputerowy Avago-technologies eXtremeRAID 2000. Avago Technologies eXtremeRAID 2000 User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 84
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
eXtremeRAID 2000
Installation Guide
DB11-000028-00 First Edition
08P5517
Przeglądanie stron 0
1 2 3 4 5 6 ... 83 84

Podsumowanie treści

Strona 1 - Installation Guide

eXtremeRAID 2000Installation GuideDB11-000028-00 First Edition08P5517

Strona 3 - 408.433.8000

About This ManualThis installation guide covers hardware setup and configuration procedures necessary for the installation of a Mylex eXtremeRAID™ 20

Strona 4 - Declaration of Conformity

ConventionsThroughout this manual, the following conventions are used to describe user interaction with the product:prompt This style of type indicate

Strona 5

Manual No. BD11-000028-00 iiiContentsChapter 1IntroductionThe Mylex eXtremeRAID 2000 Controller ... 1-1Controll

Strona 6 - Community of Europe

iv eXtremeRAID 2000 Installation GuideBattery Backup Capacity ...A-2Maintenance ...

Strona 7

Manual No. BD11-000028-00 vSAF-TE ...E-1GlossarySOFTWARE LI

Strona 8 - Copyright Notice

vi eXtremeRAID 2000 Installation Guide

Strona 9 - Trademark Acknowledgments

Manual No. DB11-000028-00 1-1Chapter 1IntroductionThis chapter describes:• The eXtremeRAID™ 2000 controller• Standard package contents• User-supplie

Strona 10

The Mylex eXtremeRAID 2000 Controller1-2 eXtremeRAID 2000 Installation Guideprovides the speed and functionality required by high demand server platfo

Strona 11 - About This Manual

IntroductionManual No. DB11-000028-00 1-3Controller FeaturesFeatures of the eXtremeRAID 2000 controller include:• Up to four Ultra 160 SCSI channels t

Strona 12 -  WARNING

Electromagnetic Compatibility NoticesThis device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This

Strona 13 - Contents

Standard Package Contents1-4 eXtremeRAID 2000 Installation GuideStandard Package ContentsThe following items are supplied with the standard shipping p

Strona 14 - Enclosure Management

IntroductionManual No. DB11-000028-00 1-5User-Supplied ItemsThe following user-supplied items are required to perform this installation:• IBM-PC™ comp

Strona 15 - Glossary

User-Supplied Items1-6 eXtremeRAID 2000 Installation Guide

Strona 16

Manual No. DB11-000028-00 2-1Chapter 2InstallationThis chapter describes:• Preparation• Connectors, jumpers, and LEDs• Controller installation procedu

Strona 17 - Introduction

Connectors, Jumpers, and LEDs2-2 eXtremeRAID 2000 Installation GuideConnectors, Jumpers, and LEDsUp to four Ultra 160 SCSI channels are supported on t

Strona 18

InstallationManual No. DB11-000028-00 2-3Table 2-1. Jumper DescriptionsJumper Description Default SettingJP1 N/A -JP2 pins 1–2 normal, pins 2–3 blank

Strona 19

Controller Installation Procedures2-4 eXtremeRAID 2000 Installation GuideController Installation ProceduresThis section describes how to install the M

Strona 20 - Standard Package Contents

InstallationManual No. DB11-000028-00 2-55. Plug the controller firmly into an available 32-bit or 64-bit PCI slot so that the controller’s external c

Strona 21 - User-Supplied Items

Controller Installation Procedures2-6 eXtremeRAID 2000 Installation Guide7. Enable termination for the device(s) at the end(s) of each SCSI bus or att

Strona 22

InstallationManual No. DB11-000028-00 2-7• If the drives are in an external cabinet, connect a wide, 68-pin Very High Density Component Interconnect (

Strona 23 - Installation

Interference-Causing Equipment Regulations.Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur

Strona 24 - Connectors, Jumpers, and LEDs

SCSI Termination Guidelines2-8 eXtremeRAID 2000 Installation GuideSCSI Termination GuidelinesTo maintain proper voltage levels for SCSI control and da

Strona 25

InstallationManual No. DB11-000028-00 2-9Figure 2-4. Internal Drive Termination ExampleFigure 2-5. Internal -External Termination Example☛ NoteWhen co

Strona 26

SCSI Cabling Guidelines2-10 eXtremeRAID 2000 Installation GuideSCSI Cabling GuidelinesThe eXtremeRAID 2000 supports up to four Ultra 160 SCSI channels

Strona 27 - Manual No. DB11-000028-00 2-5

InstallationManual No. DB11-000028-00 2-11External SCSI ConnectorsThe external SCSI connectors on the controller are female, Very High Density Compone

Strona 28

SCSI Cabling Guidelines2-12 eXtremeRAID 2000 Installation Guide

Strona 29 - Manual No. DB11-000028-00 2-7

Manual No. DB11-000028-00 3-1Chapter 3Controller Start-UpThis chapter describes:•BIOS Options• BIOS Configuration Utility (RAID EzAssist)• Operating S

Strona 30 - SCSI Termination Guidelines

BIOS Options3-2 eXtremeRAID 2000 Installation Guide Setting BIOS OptionsThe available BIOS options are:• BIOS disabled / enabled• CD-ROM boot disabled

Strona 31 - Manual No. DB11-000028-00 2-9

Controller Start-UpManual No. DB11-000028-00 3-3Enable 8 GByte or 2 GByte DrivesThis setting affects how the BIOS reads the disk drives for the boot p

Strona 32 - SCSI Cabling Guidelines

BIOS Configuration Utility (RAID EzAssist)3-4 eXtremeRAID 2000 Installation Guide☛ NoteIn the event that the RAID controller needs to be replaced, the

Strona 33 - External SCSI Connectors

Controller Start-UpManual No. DB11-000028-00 3-5Global Array Manager (GAM) ClientThe controller can be configured using Global Array Manager Client. G

Strona 34

Declaration of ConformityPer FCC Part 2, Section 2.1077(a)Manufacturer’s Name: LSI Logic Corporation Manufacturer’s Address:North American Headquarter

Strona 35 - Controller Start-Up

In Case of Problems3-6 eXtremeRAID 2000 Installation Guide

Strona 36 - Setting BIOS Options

Manual No. DB11-000028-00 A-1Appendix AMemory Module andBattery Backup UnitFigure A-1. BDIMM with BBUProduct DescriptionThe Battery Dual Inline Memory

Strona 37

BDIMM OperationA-2 eXtremeRAID 2000 Installation GuideBDIMM Operation This BDIMM consists of 32 MB, 64 MB, 128 MB, or 256 MB of Error Correction Code

Strona 38 - Operating System

Memory Module and Battery Backup UnitManual No. DB11-000028-00 A-3Maintenance No maintenance is required. However, we recommend that the BDIMM charge

Strona 39 - In Case of Problems

BDIMM Functional DescriptionA-4 eXtremeRAID 2000 Installation GuideStatus Indication Battery status can be checked using the Intelligent Battery Backu

Strona 40

Memory Module and Battery Backup UnitManual No. DB11-000028-00 A-5BDIMM Specifications Onboard Battery Electrical Properties• One lithium-ion cell, 4.

Strona 41 - Battery Backup Unit

BDIMM SpecificationsA-6 eXtremeRAID 2000 Installation Guide

Strona 42 - BDIMM Operation

Manual No. DB11-000028-00 B-1Appendix BeXtremeRAID 2000SpecificationsGeneral Hardware SpecificationseXtremeRAID 2000Controller eXtremeRAID 2000CPU Str

Strona 43

Environmental SpecificationsB-2 eXtremeRAID 2000 Installation GuideEnvironmental SpecificationsController eXtremeRAID 2000Temperature Operating 0°C to

Strona 44 - Battery and Charge Circuit

Manual No. DB11-000028-00 C-1Appendix CeXtremeRAID 2000Error Messages☛ NoteThe firmware you are using may have these messages turned off. However, the

Strona 45 - BDIMM Specifications

Declaration of ConformityPer 89\336\EECResponsible PartyName:LSI Logic Corporation Address:North American HeadquartersMilpitas, CAU.S.A.hereby declare

Strona 46

Installation AbortC-2 eXtremeRAID 2000 Installation GuideDuring the initialization, if the firmware fails to respond to the BIOS inquiry within two mi

Strona 47 - Specifications

eXtremeRAID 2000 Error MessagesManual No. DB11-000028-00 C-3With Firmware 6.x, if the BIOS displays a mismatch in the Configuration on Disk (COD) on a

Strona 48 - Environmental Specifications

System Reboot or Power DownC-4 eXtremeRAID 2000 Installation Guide

Strona 49

Manual No. DB11-000028-00 D-1Appendix DPCI Hot PlugIntroductionPCI Hot Plug is a feature that allows a PCI card to be replaced while the host system i

Strona 50 - Installation Abort

ImplementationD-2 eXtremeRAID 2000 Installation Guide• odineb.nlm - This is a module combining the Open Datalink interface and the Novell Event Bus (N

Strona 51 - System Reboot or Power Down

PCI Hot PlugManual No. DB11-000028-00 D-3Windows NTWindows NT requires additional software from the vendor who makes the system. Because this software

Strona 52

ImplementationD-4 eXtremeRAID 2000 Installation Guidethe PCI Hot Plug capability. No additional software is required.Please refer to the Windows XP or

Strona 53

Manual No. xxxxxx E-1Appendix EEnclosure ManagementIntroductionMylex’s eXtremeRAID controllers support the industry standard enclosure management prot

Strona 54 - Implementation

SAF-TEE-2 eXtremeRAID 2000 Installation Guide

Strona 55

Manual No. xxxxxx G-1GlossaryAcceleRAID™The AcceleRAID family features high performance, cost effective Ultra SCSI/Ultra2 SCSI LVD and Ultra 160 SCSI

Strona 56

Community of EuropeCE mark is rated for the eXtremeRAID 2000 as follows: CISPR 22 Radiated EmissionEN55022, Generic immunity standard for the followin

Strona 57

G-2 eXtremeRAID 2000 Installation GuideAutomatic RebuildMylex controllers provide automatic rebuild capabilities in the event of a physical disk drive

Strona 58

GlossaryManual No. xxxxxx G-3BusA set of conductors that connect the functional units in a computer and are the channels through which data is transfe

Strona 59

G-4 eXtremeRAID 2000 Installation GuideSCSI bus on a disk array controller. Each disk array controller provides at least one channel.Conservative Cach

Strona 60

GlossaryManual No. xxxxxx G-5Disk ArrayA collection of disks from one or more commonly accessible disk systems. Disk arrays, also known as RAID, allow

Strona 61 - Manual No. xxxxxx G-3

G-6 eXtremeRAID 2000 Installation GuideECCError Correcting Code, a method of generating redundant information which can be used to detect and correct

Strona 62

GlossaryManual No. xxxxxx G-7FailbackRestoring a failed system component’s share of a load to a replacement component.FailoverA mode of operation for

Strona 63 - Manual No. xxxxxx G-5

G-8 eXtremeRAID 2000 Installation GuideGigabyte230 (1,073,741,824) bytes. Abbreviated as G or GB.Global Array Manager (GAM)A Mylex RAID management uti

Strona 64

GlossaryManual No. xxxxxx G-9controller to “rebuild” the data on the new drive, all without interrupting system operations. Once the rebuild is comple

Strona 65 - Manual No. xxxxxx G-7

G-10 eXtremeRAID 2000 Installation GuideI/OInput/Output, the transmission of information between an external source and the computer.I/O BusAny path u

Strona 66

GlossaryManual No. xxxxxx G-11Logical Drive StatesA logical (system) drive can be Online, Critical, or Offline. Notice that the term “online” is used

Strona 67 - Manual No. xxxxxx G-9

Underwriters Laboratories Statement and Warning WARNING! This controller is furnished with a nonvolatile RAM (NVRAM) chip that uses a sealed lithium b

Strona 68

G-12 eXtremeRAID 2000 Installation GuideMirroringRefers to the complete duplication of data on one disk drive to another disk drive, this duplication

Strona 69 - Manual No. xxxxxx G-11

GlossaryManual No. xxxxxx G-13OfflineA Logical Drive is in an “offline” state if no data can be read from it or written to it. Offline does not apply

Strona 70 - Narrow SCSI

G-14 eXtremeRAID 2000 Installation GuidePhysical DeviceAny device connected to some kind of hardware. For example, SCSI disk, fibre disk, network disk

Strona 71 - Manual No. xxxxxx G-13

GlossaryManual No. xxxxxx G-15RAID LevelsMylex disk array controllers support four RAID Advisory Board approved (RAID 0, RAID 1, RAID 3, and RAID 5),

Strona 72

G-16 eXtremeRAID 2000 Installation GuideRAID MigrationA feature in RAID subsystems that allows for changing a RAID level to another level without powe

Strona 73 - RAID Levels

GlossaryManual No. xxxxxx G-17enclosure itself is treated as simply another device on the SCSI bus. Many other leading server, storage, and RAID contr

Strona 74

G-18 eXtremeRAID 2000 Installation GuideOffline: A SCSI disk drive is in a “offline” state if it is not present, if it is present but not powered on,

Strona 75 - SCSI Drive States

GlossaryManual No. xxxxxx G-19reported, conservative cache is enabled and all system drives are switched to write-through cache. Primarily used in fib

Strona 76

G-20 eXtremeRAID 2000 Installation GuideTo use the standby rebuild feature, you should always maintain a standby SCSI disk in your system. When a disk

Strona 77 - SAME DAC960 controller

GlossaryManual No. xxxxxx G-21drive 1, block 2 on SCSI drive 2, block 3 on SCSI drive 3, block 4 on SCSI drive 1, block 5 on SCSI drive 2, and so on.

Strona 78 - Striping

Proprietary Rights NoticeThis document contains proprietary information of LSI Logic Corporation. The information contained herein is not to be used b

Strona 79 - Manual No. xxxxxx G-21

G-22 eXtremeRAID 2000 Installation GuideUltra SCSI (Fast 20 SCSI)A high performance SCSI protocol that has a bus speed of 20 Megabytes per second in t

Strona 80

LSI LOGIC CORPORATIONSOFTWARE LICENSE AND WARRANTY POLICYLimited WarrantyLSI warrants to the original purchaser of the product enclosed herein(“Custom

Strona 81 - LSI LOGIC CORPORATION

with LSI’s instructions and the terms of this Agreement, shippingcosts to be borne by LSI, and (c) Customer has provided proof ofpurchase price and da

Strona 82

is a part of the Product (“LSI Software”) solely as part of the Productincorporated into the OEM Products that and not on a standalonebasis. Customer

Strona 83

Manual No. DB11-000028-0008P5517LSI Logic CorporationNorth American HeadquartersMilpitas, CA408.433.8000

Strona 84

Trademark AcknowledgmentsLSI Logic, the LSI Logic logo, MORE, Mylex, and SANmapping are trademarks or registered trademarks of LSI Logic Corporation.

Komentarze do niniejszej Instrukcji

Brak uwag